Hot Water Booster Coils

Booster Coil

There are many existing systems that require the addition of cooling to a heating-only unit. Systems need to keep pace with changing requirements for spaces that include a mandatory requirement for cooling. Existing systems can already have cooling, but a booster will have to be placed into the system to add additional cooling.   When cooling is added, it must be decided whether the tonnage can be...

Read More
Sentry Guard

Operating water coils that are prone to air temperatures below freezing normally need the use of anti-freeze. The most common is glycol. This has been used for over 40 years, and there are two common types, ethylene and propylene. Anti-freeze provides a safeguard if there are mechanical or electrical breakdowns that may cause fluid to sit in a coil with below freezing air going across...

Read More
Dirty Coil

Finned tube coils are meant to have contact with the air flow, as more contact creates more heat transfer. Heat transfer is nothing more than heat exchanged from one medium to another, and the goal is to create maximum heat transfer efficiency. The downside to this process is the coil’s susceptibility to foreign materials becoming lodged in them. The following explores this problem in a...

Read More
Booster Coil

Many projects require downstream duct mounted coils to heat or cool air to its final desired temperature. Normally there are upstream coils that regulate the leaving air temperature to a design intermediate level. The duct coil takes the air from that intermediate level to its final desired temperature. Many systems can vary the air flow or water volume to achieve a desired leaving air temperature...

Read More
Outside Air Loads

HVAC and process heating/cooling must deal with the added tonnage created by using fresh air from outside. Most times, the requirement for fresh air is mandatory and can go from 10% all the way to 100 % of the system air flow. There are numerous rules and regulations written to eliminate air flow quality problems, including bacteria and other micro-organisms, that can cause health problems....

Read More
Corrosion in Tube

There are many reasons why hot water coils in your system can under-perform. Some reasons are from the time of the design, and many other instances can also occur after the coils have been installed. Here are 10 common reasons why hot water heating coils can fail:   Air stratification issues - The air flow across the surface of the coil is not being evenly...

Read More
Hot Water Coil

Water Cooling and Heating Coils   Water is the most widely used heat transfer medium because it’s readily available and low in cost. Water can be used as a heat transfer medium if the temperature range is between 15 degrees Fahrenheit (when mixed with glycol) when cooling and a high of 210 degrees Fahrenheit when heating.   Chilled Water Coils   When maintaining an acceptable living or working condition in...

Read More
Replacement Coils

Coil replacement has been a part of the HVAC aftermarket for as long as finned tube coils have been used to create heat transfer. The coils installed in the 50’s and 60’s were heavier duty than today’s coils and were almost always spiral fin type with a tension wound fin onto copper tubes.  The plate fin didn’t become prevalent until the mid-60’s. By the end...

Read More
Plugged Coil

  Replacing heat exchanger coils was adapted ever since the beginning of the HVAC and processing/cooling era. It’s now close to 90 years since the first finned tube heat exchangers appeared on the market in the early 1900’s. The coil has undergone drastic changes over the years, from the spiral wound type to the plate fin coils that currently dominate the market. Throughout each decade, the...

Read More
Hot Water Coils

If you’re in the HVAC industry, then you’ve been involved in projects and installations that have duct mounted booster heating coils. How did the term “booster” originate? Most heating coil applications have a main heating coil that takes air from the lowest entering air temperature to an intermediate air temperature. Each individual space has its own heat load, and the duct mounted booster coil is...